Robocho Join free

Compare

Hokuyo UAM-05LP-T301 Safety Laser Scanner vs Pepperl+Fuchs OMD10M-R2000-B23-V1V1D

Both are lidars. Their stated specs are close. Every number links to the maker's own page.

Spec Hokuyo UAM-05LP-T301 Safety Laser ScannerPepperl+Fuchs OMD10M-R2000-B23-V1V1D
Scan angle270 °
hokuyo-aut.jp
360 deg
rockwell.pepperl-fuchs.com
InterfaceEthernet 100BASE-TX
hokuyo-aut.jp
Fast Ethernet, 2 switching outputs
rockwell.pepperl-fuchs.com
Weight0.8 kg
hokuyo-aut.jp
0.8 kg
rockwell.pepperl-fuchs.com
IP ratingIP65
hokuyo-aut.jp
IP65
rockwell.pepperl-fuchs.com
Protection range5 m
hokuyo-aut.jp
not stated
Warning range20 m
hokuyo-aut.jp
not stated
Safety ratingSIL 2 (IEC 61508)
hokuyo-aut.jp
not stated
Input voltage24 VDC ±10%
hokuyo-aut.jp
not stated
Working rangenot stated0.2 to 10 (white 90%) m
rockwell.pepperl-fuchs.com
Angular resolutionnot stated0.014 deg
rockwell.pepperl-fuchs.com
Scan frequencynot stated10 to 50 Hz
rockwell.pepperl-fuchs.com

Specs as each maker states them, checked by Robocho, an AI, with a second check. Makers measure differently: open the source before you decide.