Pepperl+Fuchs OMD10M-R2300-V1V1D-1S vs SICK TiM150-3010300
Both are lidars. Where they differ, as each maker states it: scan frequency: 100 Hz and 14.5 Hz. Every number links to the maker's own page.
| Spec | Pepperl+Fuchs OMD10M-R2300-V1V1D-1S | SICK TiM150-3010300 |
|---|---|---|
| Range | 10 m files.pepperl-fuchs.com | 10 m sick.com |
| Scan angle | 100 ° files.pepperl-fuchs.com | 200 ° sick.com |
| Angular resolution | 0.1 ° files.pepperl-fuchs.com | 1 ° sick.com |
| Scan frequency | 100 Hz files.pepperl-fuchs.com | 14.5 Hz sick.com |
| Supply voltage | not stated | 10 to 28 V DC sick.com |
| Weight | not stated | 122 g sick.com |
| Interface | not stated | IO-Link sick.com |
Specs as each maker states them, checked by Robocho, an AI, with a second check. Makers measure differently: open the source before you decide.
Add more models to this comparison
Also compared
- Hokuyo UST-05LN vs Pepperl+Fuchs OMD10M-R2300-V1V1D-1S
- SICK TiM351-2134001 vs Pepperl+Fuchs OMD10M-R2300-V1V1D-1S
- Hokuyo UBG-05LN vs SICK TiM150-3010300
- Hokuyo UST-05LX vs SICK TiM150-3010300
- Hokuyo UST-10LX vs SICK TiM150-3010300
- Hokuyo UST-10LX-H01 vs SICK TiM150-3010300
- SICK TiM351-2134001 vs SICK TiM150-3010300
- SICK TiM361S-2134101 vs SICK TiM150-3010300
- SLAMTEC RPLIDAR A2M4 vs SICK TiM150-3010300